ROLPIN UTI
Rolpin UTI is a plywood made of MARITIME PINE (French origin). Used for packaging, caisson, lost formwork, bracing, non-visible structures and site protection.
Format: 2500 x 1250 mm
The Plus :
– Very resistant panels
– NF Exterior CTB-X Structure
Variants :
– UTI III+/III : One side sanded
Options:
– Cutting and machining on request.
Where to find this product?
See identical face and counterface:
UTI is the ideal solution for use in walls and floors. Resistance, durability and competitive price.
Product features
Face | Unrepaired face, admitting knotholes and cracks |
Counterface | Unrepaired face, admitting knotholes and cracks |
Finish | The 2 faces are not sanded |
Variants
Features
Standards
Read more
Variants
UTI III+/III | One side chewed and sanded |
Features
Dimensions | 2500 x 1250 mm (other formats on request) |
Thicknesses | From 7 to 38 mm |
Number of folds | From 3 to 13 |
Packing | From 85 to 15 |
Density | 560 to 610 kg/m3 |
Uses | Packaging, caisserie, lost formwork, bracing, non-visible structures and site protection. |
Collage | According to EN 314-2: bonding class 3 “outdoor environments”, water and weather resistant. Phenolic glue. |
Options | Cutting and machining on request. |
Standards
Structural uses in construction | System 2+ certificate of conformity according to EN 13986 + A1 |
Outdoor environments | According to EN 636 + A1 (structural use). Approved to the French quality mark NF Extérieur CTBX and to the German mark BFU 100 DIN 68705 part 3. |
Release of formaldehyde | Classification E1 According to EN 717.2 Formaldehyde emission measurements show a release of 0.02 mg/l of air according to the ISO 12460-4 desiccant method. This value is 15 times lower than the requirements of the Japanese standard F****, the most stringent in the world (0.3 mg/l) according to JIS A 1460. |
Reaction to fire classification | According to EN 13501-1 + A1 Thickness > 9 mm : Euroclass D-s2, d0 |
CE marking | n° 380 – CPD – 011 – EN 13986 + A1 |
Read more
Storage | It is advisable to store the packages in a dry place, preferably flat and level on dry rafters insulating them from the ground. The spacing between rafters is to be adapted to the thickness and nature of the stored panels. When storing in multiple stacks, align the rafters in height. On site, provide shelter or cover the panels with a waterproof but vapor permeable coating. |
Implementation | Comply with the rules of art, safety and DTU in force. |
Dimensional tolerances of the panels | They comply with the specifications of the EN 315 standard:
|
Other features | Thermal conductivity Pentachlorophenol content λ = 0,13W/.K |
For more information and to consult the mechanical characteristics, download the data sheet available below.